Duo Setup
SpoolEase Duo is still at the beta stage, so setting it up is less straightforward, though it is not difficult.
New users
This is for users who are installing SpoolEase for the first time or want to start from scratch, ignoring the previous configuration:
- Set up the system based on the Console Setup instructions, but make sure to flash Console version 0.8.x or later.
- Continue to Setting up the local scale below.
Existing users
These instructions are specific to those who are upgrading their console and want to take the safest path due to the new flash layout update step. Therefore, for now, it is a two-stage upgrade process.
- Back up the spools database from the SpoolEase web app, just in case.
- Connect the device to a computer with USB for the next several steps:
- https://thelastoutpostworkshop.github.io/ESPConnect/
- Flash Tools -> inside Flash Backup & Erase, press "Download Flash Backup" to download a backup of the entire flash.
- Serial Monitor -> Reset to get it working again (or just disconnect from power and reconnect).
You now have a backup of your entire flash, so you will be able to roll back in case something goes wrong.
- Upgrade the console to the latest version you see in the Software Update screen on the device (currently 0.7.7).
Upgrading to 0.8.0-b.x
-
In the SpoolEase web application (reachable via http://device-ip), go to the Gear Icon (top right) -> "Debug" tab -> "One-Off update" section, fill in the edit box for the console update name Update-to-Duo, and press the "Update Console" button.
It will update the Duo firmware again. It will then go through a 'One Time Flash Layout Update', potentially twice, depending on the state of the device being updated. Once that is complete, your Duo will be using version 0.8.0-b.7 or higher and ready to enable the local scale. -
Continue to Setting up the local scale below.
Rollback procedure
In the unlikely event that something fails during the flash upgrade, you can roll back to your previous version using the following steps:
- https://thelastoutpostworkshop.github.io/ESPConnect/
- Flash Tools -> inside "Flash Firmware", select the firmware binary that was backed up and flash it to offset 0x0. It is sometimes slow to start or even displays initial progress that hangs for some time and then continues. If this fails, disconnect the device, reconnect it, and try again.
- Restart the device.
Setting up the local scale
-
To enable the local scale, go to http://device-ip/config. Under the "Scales Settings" section, select the checkbox for "Local HX711 Scale Available".
If you have also configured a separate SpoolEase scale unit, you will need to select which scale should be the default (relevant when spools are placed on both devices at the same time).
"Apply" the settings and "Restart Device". -
The local scale should now be enabled.
Review the Scale Setup page for instructions on how to calibrate the scale. If you have two scales configured, make sure the page for the local scale is selected on the calibration page.